mirror of
https://github.com/gnu4cn/ccna60d.git
synced 2024-05-21 04:55:00 +08:00
Updated 'src/network_troubleshooting.md'.
This commit is contained in:
parent
c701c3e4dc
commit
1f22084103
@ -71,3 +71,4 @@
|
||||
- [附录一:华为交换机端口镜像](port-mirroring.md)
|
||||
- [附录二:IPv6地址空间](IPv6_address_space.md)
|
||||
- [附录三:GNS3简介](GNS3_tutorial.md)
|
||||
- [附录三:网络故障排除](network_troubleshooting.md)
|
||||
|
76
src/network_troubleshooting.md
Normal file
76
src/network_troubleshooting.md
Normal file
@ -0,0 +1,76 @@
|
||||
# 网络故障排除
|
||||
|
||||
本文记录网络故障排除,以备今后遇到同样问题时,快速解决。
|
||||
|
||||
|
||||
## 光模块起不来的问题
|
||||
|
||||
|
||||
光模块起不来,通常是因为所使用的光模块,与光纤不匹配的原因造成。其中,多模光模块使用 810nm 波长的激光,而单模光模块则使用 1310nm 波长的激光。有关单模与多模的区别,请参考:[Fiber Optic Cable Types: Single Mode vs Multimode Fiber Cable](https://community.fs.com/article/single-mode-cabling-cost-vs-multimode-cabling-cost.html)。排查此问题的三个命令(H3C):
|
||||
|
||||
|
||||
- `display transceiver interface Ten-GigabitEthernet 1/0/52`
|
||||
|
||||
|
||||
输出:
|
||||
|
||||
|
||||
```console
|
||||
[xfoss-com-core]display transceiver interface Ten-GigabitEthernet 1/0/52
|
||||
Ten-GigabitEthernet1/0/52 transceiver information:
|
||||
Transceiver Type : 10G_BASE_SR_SFP
|
||||
Connector Type : LC
|
||||
Wavelength(nm) : 850
|
||||
Transfer Distance(m) : 80(OM2),30(OM1),300(OM3)
|
||||
Digital Diagnostic Monitoring : YES
|
||||
Vendor Name : XFOSS-COM
|
||||
Vendor Part Number : SFPXG-850C-D30
|
||||
Part Number : SFPXG-850C-D30
|
||||
Serial Number : 012345678901
|
||||
```
|
||||
|
||||
- `display transceiver manuinfo interface Ten-GigabitEthernet 1/0/52`
|
||||
|
||||
|
||||
输出:
|
||||
|
||||
|
||||
```console
|
||||
[xfoss-com-core]display transceiver manuinfo interface Ten-GigabitEthernet 1/0/51
|
||||
Ten-GigabitEthernet1/0/51 transceiver manufacture information:
|
||||
Manu. Serial Number : 01234567890123456789
|
||||
Manufacturing Date : 2017-04-01
|
||||
Vendor Name : XFOSS-COM
|
||||
```
|
||||
|
||||
|
||||
- `display transceiver diagnosis interface Ten-GigabitEthernet 1/0/51`
|
||||
|
||||
输出:
|
||||
|
||||
|
||||
```console
|
||||
[xfoss-com-core]display transceiver diagnosis interface Ten-GigabitEthernet 1/0/51
|
||||
Ten-GigabitEthernet1/0/51 transceiver diagnostic information:
|
||||
Current diagnostic parameters:
|
||||
Temp.(C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
|
||||
42 3.41 6.42 -2.55 -2.71
|
||||
Alarm thresholds:
|
||||
Temp.(C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
|
||||
High 80 3.60 15.00 0.00 0.00
|
||||
Low -15 3.00 0.00 -10.90 -8.30
|
||||
```
|
||||
|
||||
|
||||
- `display transceiver alarm interface Ten-GigabitEthernet 1/0/52`
|
||||
|
||||
|
||||
输出:
|
||||
|
||||
|
||||
```console
|
||||
[xfoss-com-core]display transceiver alarm interface Ten-GigabitEthernet 1/0/52
|
||||
Ten-GigabitEthernet1/0/52 transceiver current alarm information:
|
||||
RX power low
|
||||
RX signal loss
|
||||
```
|
Loading…
Reference in New Issue
Block a user