diff --git a/src/SUMMARY.md b/src/SUMMARY.md index 5adc0f6..e7f4cf9 100644 --- a/src/SUMMARY.md +++ b/src/SUMMARY.md @@ -71,3 +71,4 @@ - [附录一:华为交换机端口镜像](port-mirroring.md) - [附录二:IPv6地址空间](IPv6_address_space.md) - [附录三:GNS3简介](GNS3_tutorial.md) +- [附录三:网络故障排除](network_troubleshooting.md) diff --git a/src/network_troubleshooting.md b/src/network_troubleshooting.md new file mode 100644 index 0000000..2091f4e --- /dev/null +++ b/src/network_troubleshooting.md @@ -0,0 +1,76 @@ +# 网络故障排除 + +本文记录网络故障排除,以备今后遇到同样问题时,快速解决。 + + +## 光模块起不来的问题 + + +光模块起不来,通常是因为所使用的光模块,与光纤不匹配的原因造成。其中,多模光模块使用 810nm 波长的激光,而单模光模块则使用 1310nm 波长的激光。有关单模与多模的区别,请参考:[Fiber Optic Cable Types: Single Mode vs Multimode Fiber Cable](https://community.fs.com/article/single-mode-cabling-cost-vs-multimode-cabling-cost.html)。排查此问题的三个命令(H3C): + + +- `display transceiver interface Ten-GigabitEthernet 1/0/52` + + +输出: + + +```console +[xfoss-com-core]display transceiver interface Ten-GigabitEthernet 1/0/52 +Ten-GigabitEthernet1/0/52 transceiver information: + Transceiver Type : 10G_BASE_SR_SFP + Connector Type : LC + Wavelength(nm) : 850 + Transfer Distance(m) : 80(OM2),30(OM1),300(OM3) + Digital Diagnostic Monitoring : YES + Vendor Name : XFOSS-COM + Vendor Part Number : SFPXG-850C-D30 + Part Number : SFPXG-850C-D30 + Serial Number : 012345678901 +``` + +- `display transceiver manuinfo interface Ten-GigabitEthernet 1/0/52` + + +输出: + + +```console +[xfoss-com-core]display transceiver manuinfo interface Ten-GigabitEthernet 1/0/51 +Ten-GigabitEthernet1/0/51 transceiver manufacture information: + Manu. Serial Number : 01234567890123456789 + Manufacturing Date : 2017-04-01 + Vendor Name : XFOSS-COM +``` + + +- `display transceiver diagnosis interface Ten-GigabitEthernet 1/0/51` + +输出: + + +```console +[xfoss-com-core]display transceiver diagnosis interface Ten-GigabitEthernet 1/0/51 +Ten-GigabitEthernet1/0/51 transceiver diagnostic information: + Current diagnostic parameters: + Temp.(C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm) + 42 3.41 6.42 -2.55 -2.71 + Alarm thresholds: + Temp.(C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm) + High 80 3.60 15.00 0.00 0.00 + Low -15 3.00 0.00 -10.90 -8.30 +``` + + +- `display transceiver alarm interface Ten-GigabitEthernet 1/0/52` + + +输出: + + +```console +[xfoss-com-core]display transceiver alarm interface Ten-GigabitEthernet 1/0/52 +Ten-GigabitEthernet1/0/52 transceiver current alarm information: + RX power low + RX signal loss +```